ACTi E66 Przewodnik Instalacji Strona 11

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 10
E-11
T
XD
R
TS
SW4
SW5
SW7
SW6
SW8
TXA
TXB
RXA
COM3
RXB
Table (1) DIPSW1
("When using USB" are the DIPSW1 factory settings.)
DIPSW2 (SW4 to SW8) in the above table 2 operate as shown in the circuit
diagram below.
Fig. 1 DIPSW2 (SW4 to SW8) circuit diagram
DIPSW1
No.
Description ON OFF
When using
USB
When using
COM4
1 Used by the system Reserved Reserved OFF OFF
2
Changes Touch Panel's communciation method COM4 USB
OFF ON
3
Switches the COM4 Touch Panel Receive Data
Communication ON or OFF
Available NOT Available
OFF ON
4
Switches the COM4 Touch Panel Send Data
Communication ON or OFF
Available NOT Available
OFF ON
5
Switches the External Device's
usage of COM4
ON or OFF
Available NOT Available
OFF ON
6 Switches the USB Reference Voltage ON or OFF Available NOT Available ON OFF
7
Switches the USB Touch Panel Possitive (+) Data
Communication ON or OFF
Available NOT Available
ON OFF
8
Switches the USB Touch Panel Negative (-) Data
Communication ON or OFF
Available NOT Available
ON OFF
Table (2) DIPSW2
(Factory settings are all OFF.)
*1 If you use termination resistance, base your setiings on your connection specifica-
tions.
DIPSW2
No.
Description ON OFF RS-232C RS-422 RS-485
1
Changes COM1 (RS-232C)
#9 pin (RI <-> +5V)
+5V 500mA external output
possible
RI
ON/OFF ON/OFF ON/OF
F
2
Changes COM3's
communciation method
RS-422/RS-485 RS-232C
OFF ON ON
3
Changes COM2 (RS-232C)
#9 pin (RI <-> +5V)
+5V 500mA external output
possible
RI
ON/OFF ON/OFF ON/OF
F
4
Changes TX data's output
mode
TX data output is controlled via
the RTS signal
TX data output is
NOTcontrolled via the RTS
signal. (normally output)
OFF ON/OFF ON
5
Switches the TX termination
resistance ON/OFF
Inserts termination resistance of
220
between TXA and TXB.
No termination
OFF ON
ON/OFF
*1
6
Switches the RX termination
resistance ON/OFF
Inserts termination resistance of
220
between RXA and RXB.
No termination
OFF ON
ON/OFF
*1
7
Switches the shorting of TXA
and RXA ON or OFF
Shorts TXA and RXA
(RS-485 mode)
No shorting
(RS-422 mode)
OFF OFF ON
8
Switches the shorting of TXB
and RXB ON or OFF
Shorts TXB and RXB
(RS-485 mode)
No shorting
(RS-422 mode)
OFF OFF ON
9
Changes COM3's
communciation method
RS-422/RS-485 RS-232C
OFF ON ON
10
Used by the system Reserved Reserved
OFF OFF OFF
Przeglądanie stron 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 19 20

Komentarze do niniejszej Instrukcji

Brak uwag